AJH Synth Sample Hold & Slew
Sample Hold & Slew
12 HP Eurorack module
A 12 HP utility combining sample-and-hold and track-and-hold with Restrict, colour-shaped regular or clipped noise, a wide-range clock source, and gated linear or exponential slew.
Features
- Generates random and pseudo-random control voltages, staircase waveforms, audio aliasing effects, portamento-style effects, and adjustable audio-range noise.
- Restrict limits how far the held output moves after each sample while retaining the input's overall range over successive holds.
- External high-rate clocking lets the sample-and-hold section create downsampling effects.
- The gated slew generator can operate independently or in series with the sample-and-hold section.
- Noise, clock, sample/track-and-hold, and slew functions can operate simultaneously as separate utilities.
Controls & Jacks (19)
- Noise Colour— Shapes the analogue noise: centre leaves it unfiltered, counterclockwise applies low-pass filtering, and clockwise applies high-pass filteri
- Slew Output— Outputs the slewed control-voltage signal.
- Clock Output— Outputs the internal ±5 V square-wave clock/LFO.
- Restrict— Controls how strongly each newly sampled value is constrained by the preceding held value; fully counter-clockwise gives conventional sample
- Slew Time— Sets the slew or lag-generator time constant.
- Slew Input— Input to the slew generator; patching it overrides the normalled sample-and-hold output.
- Clock Input— Clock input for the sample-and-hold section; an external signal overrides the normalled internal clock.
- Noise Output— Outputs the colour-shaped analogue noise signal.
- Sample Output— Outputs the sampled or tracked signal.
- Rate— Sets the internal square-wave clock/LFO rate, from approximately one cycle every 30 seconds to over 2 kHz; fully down turns the LFO off.
- Slew Gate Input— Receives an external CV or gate pulse to switch the slew effect in or out of circuit.
- Slew Direction— Selects slew-up only, slew-down only, or slew in both directions.
- Slew Gate Logic— Reverses the control logic of the gated slew function.
- Sample Input— Signal input for the sample-and-hold section; patching it overrides the normalled noise source.
- Slew Response— Selects linear or exponential slew response.
- Clock Activity Indicator— Indicates the actual clock rate at the sample-and-hold input, including an external clock when patched.
- Slew Active Indicator— Lights when slew is active.
- Noise Type— Selects regular or clipped noise for the NOISE jack.
- Sample Mode— Selects traditional sample-and-hold or track-and-hold operation.
How-To Guides
- Make a triangle LFO
Explore the interactive Sample Hold & Slew panel on BleepDex — tap any control to learn what it does.