Patching Panda Ephemere
Dual-channel high-resolution CV recorder and looper
14 HP Eurorack module
Ephemere is a high-resolution dual-channel CV and signal recorder for Eurorack, focused on capturing, looping, and manipulating control voltages with precise playback control. Each channel records independently with variable sample rates from 172Hz to 44.1kHz, offering up to 1014 seconds of recording time, with scan, speed, and direction control for creative CV transformation. Its musical character suits live performance preparation, generative patching, and complex modulation design.
Features
- Dual-channel independent CV and signal recording
- Variable sample rate from 172Hz (1014 seconds) to 44.1kHz (4 seconds) per channel
- Dedicated attenuverter per channel; acts as offset/CV generator when no input is patched
- 6 recording modes: Manual, Manual Mult, Sync, Sync Mult, Manual Mult-G, Sync Mult-G
- 3 playback directions: Forward, Backward, Pendulum
- 2 playback modes: Loop and One Shot
- Variable playback speed control via knob and CV input per channel
- Scan control for scrubbing through recorded CV via knob and CV input per channel
- SD card save, load, and erase for signals and settings (up to 16GB)
- OLED display with Live and Playback monitoring modes
- Quantizer with customizable scale (menu items 11 and 12)
- Full per-channel calibration for ADC and DAC accuracy
Controls & Jacks (53)
- Channel 1 Record — Start/stop recording on channel 1
- Channel 1 Play/Reset — Play/reset playback on channel 1. Hold for 3 seconds to ignore triggers (useful for REC Sync mult-G).
- Channel 1 Stop — Stop playback on channel 1
- Channel 1 Speed Control — Control playback speed of channel 1 recording
- Channel 2 Record — Start/stop recording on channel 2
- Channel 2 Speed Control — Control playback speed of channel 2 recording
- Rotary — Scroll through menus and adjust parameter values
- Channel 2 Play/Reset — Play/reset playback on channel 2. Hold for 3 seconds to ignore triggers (useful for REC Sync mult-G).
- Channel 1 Scan Control — Scan through recorded CV on channel 1
- Channel 1 Input Attenuverter — Attenuate/invert incoming signal on channel 1. When nothing patched, delivers VDC offset/CV generator.
- Channel 2 Scan Control — Scan through recorded CV on channel 2
- Channel 2 Input Attenuverter — Attenuate/invert incoming signal on channel 2. When nothing patched, delivers VDC offset/CV generator.
- Channel 1 Signal Input — Audio/CV signal input for channel 1
- Channel 2 Signal Input — Audio/CV signal input for channel 2
- Channel 1 Scan CV Input — CV input to control scanning position on channel 1 recording
- Channel 2 Scan CV Input — CV input to control scanning position on channel 2 recording
- Channel 1 Record Trigger Input — Trigger input to start/stop recording on channel 1 (in sync modes)
- Channel 2 Record Trigger Input — Trigger input to start/stop recording on channel 2 (in sync modes)
- Channel 1 Play/Reset Trigger Input — Trigger input to play/reset channel 1 playback
- Channel 1 Speed CV Input — CV input to modulate playback speed on channel 1
- Channel 2 Stop — Stop playback on channel 2
- Channel 2 Play/Reset Trigger Input — Trigger input to play/reset channel 2 playback
- Channel 1 Output — Recorded/playback signal output from channel 1
- Channel 2 Speed CV Input — CV input to modulate playback speed on channel 2
- Channel 2 Output — Recorded/playback signal output from channel 2
- Select Button — Confirm menu selection and navigate menus. Hold for 2 seconds to change channel.
- MENU — Navigate through menu options
- SELECT — Confirm menu selection and navigate menus. Hold for 2 seconds to change channel.
- ENCODER — Scroll through menus and adjust parameter values
- INPUT pot 1 — Attenuate/invert incoming signal on channel 1. When nothing patched, delivers VDC offset/CV generator.
- INPUT pot 2 — Attenuate/invert incoming signal on channel 2. When nothing patched, delivers VDC offset/CV generator.
- SPEED pot 1 — Control playback speed of channel 1 recording
- SPEED pot 2 — Control playback speed of channel 2 recording
- SCAN pot 1 — Scan through recorded CV on channel 1
- SCAN pot 2 — Scan through recorded CV on channel 2
- RECORD button 1 — Start/stop recording on channel 1
- RECORD button 2 — Start/stop recording on channel 2
- PLAY/RESET button 1 — Play/reset playback on channel 1. Hold for 3 seconds to ignore triggers (useful for REC Sync mult-G).
- PLAY/RESET button 2 — Play/reset playback on channel 2. Hold for 3 seconds to ignore triggers (useful for REC Sync mult-G).
- STOP button 1 — Stop playback on channel 1
- STOP button 2 — Stop playback on channel 2
- INPUT jack 1 — Audio/CV signal input for channel 1
- INPUT jack 2 — Audio/CV signal input for channel 2
- RECORD trigger input 1 — Trigger input to start/stop recording on channel 1 (in sync modes)
- RECORD trigger input 2 — Trigger input to start/stop recording on channel 2 (in sync modes)
- PLAY/RESET trigger input 1 — Trigger input to play/reset channel 1 playback
- PLAY/RESET trigger input 2 — Trigger input to play/reset channel 2 playback
- SCAN CV input 1 — CV input to control scanning position on channel 1 recording
- SCAN CV input 2 — CV input to control scanning position on channel 2 recording
- SPEED CV input 1 — CV input to modulate playback speed on channel 1
- SPEED CV input 2 — CV input to modulate playback speed on channel 2
- OUT1 — Recorded/playback signal output from channel 1
- OUT2 — Recorded/playback signal output from channel 2
How-To Guides
- Save a Recording to SD Card
- Load a Recording from SD Card
- Erase a Recording from SD Card
- Save Calibration Data
- Evolving Generative CV Loop
- Dual CV Counterpoint
- Live CV Scrubbing Performance
- Reverse Envelope for Reverse Attack Effects
- Manual Offset CV Generator
- Quantized Melodic CV Looper
- Pendulum CV Modulation
- Grid-Segmented CV Phrase Builder
Explore the interactive Ephemere panel on BleepDex — tap any control to learn what it does.